Part Number Hot Search : 
TIP35CW VC244A KAQY214 21SUR SBC82820 A58005 UMA4NT1 2SD845
Product Description
Full Text Search
 

To Download 9124-410G Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  optiswitch ? 9124-410G carrier-ethernet packet-optical aggregation mrv optiswitch ? 9124-410G is an award-winning compact carrier-ethernet packet-optical aggregation platform for 1 st and 2 nd mile optical fe, gige and 10ge ngn infrastructure. optiswitch 9124-410G provides service providers with a full suite of carrier-grade ethernet services along with high- availability, enhanced quality of services, security, packet-wdm and ethernet operation, administration and maintenance (oam) support. the uniqueness of a full suite of carrier- ethernet tools creates fexible service awareness and rigid slas to enable converged triple play, business and mobile backhaul services. optiswitch ? metro ethernet solution meets ieee, itu, ietf and mef standards, offering complete control to simplify deployment and management, while maintaining full interoperability and guaranteed service level agreements (slas). mrv unifed master-os ? control plane for metro-e services - simplifes operation and management integration with oss mef ce2.0 compliant services non-blocking hardware architecture - 24 x gige and 4 x 10ge (lan/wan) o fe, gige, 2,5g and 10ge services outstanding variety for optical layer 1 & layer 2 vpn services - epl x-connect, e-line, e-tree and e-lan - point-to-point, point-to-multipoint and multipoint-to- multipoint - any-to-any transparent cross-connect - eroadm services flexible uni/nni interfaces - 100fx/1000fx/2000fx and 10ge - same device for all aggregation scenarios - support for jumbo frames on all ports advanced traffc management with line rate performance - classifcation, policing, metering, marking per-fow qos - low-latency and precise service rates unmatched fexibility of ethernet virtual circuits - selective q-in-q and vlan translation end-to-end ethernet service oam to monitor slas - standard compliant C cfm ieee802.1ag / pm itu-t y.1731 - rfc2544 throughput measurements - ip sla measurements - efm link oam C ieee802.3ah - simplifes, monitors and troubleshoots services/applications protection mechanism - elps g.8031 and erps g.8032 - link protection 1:1 (los) and n+1 (lag) - sub 50ms sonet-like recovery and deterministic sla multicasting service for ip-tv triple play compact 2ru form factor for space saving hot-swap fully redundant power supplies and fans excellent price/performance for fast roi product highlights supports a wide range of mission-critical revenue generating gige and 10ge services - triple-play iptv, ngn voice services - business services and mobile backhaul lambda services C fiber optimization via c/dwdm integration applications datasheet business services triple play services xwdm services optiswitch 9124-410G ps2 ps1 console eia-232 l a 10ge-xfp 25 l a 10ge-xfp 26 l a 10ge-xfp 27 l a 10ge-xfp 28 tmp fan mgt rst mgt eth ! 2 1 24 23 22 24 21 23 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 add drop exp com ms9-oadm8 in out em9005 ps/ac em9005 ps/dc caution this assembly contains electronically sensitive components 47 49 51 53 55 57 59 61 47 49 51 53 55 57 59 61 optiswitch 9124-410G ps2 ps1 console eia-232 l a 10ge-xfp 25 l a 10ge-xfp 26 l a 10ge-xfp 27 l a 10ge-xfp 28 tmp fan mgt rst mgt eth ! 2 1 24 23 22 24 21 23 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 add drop exp com ms9-oadm8 in out em9005 ps/ac em9005 ps/dc caution this assembly contains electronically sensitive components 47 49 51 53 55 57 59 61 47 49 51 53 55 57 59 61 optiswitch 9124-410G ps2 ps1 console eia-232 l a 10ge-xfp 25 l a 10ge-xfp 26 l a 10ge-xfp 27 l a 10ge-xfp 28 tmp fan mgt rst mgt eth ! 2 1 24 23 22 24 21 23 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 add drop exp com ms9-oadm8 in out em9005 ps/ac em9005 ps/dc caution this assembly contains electronically sensitive components 47 49 51 53 55 57 59 61 47 49 51 53 55 57 59 61 bsc/rnc/s-gw 2g/2.5g b t s e nd - t o - end s er vic e o am 3g node b os904-mbh mgt pwr console eia-232 mgt eth l a 1 2 1 2 3 4 st1 st2 tod 1pps 50 75 50 75 clk out clk in clk ds1/e1 los os904-mbh mgt pwr console eia-232 mgt eth l a 1 2 1 2 3 4 st1 st2 tod 1pps 50 75 50 75 clk out clk in clk ds1/e1 los os904-mbh mgt pwr console eia-232 mgt eth l a 1 2 1 2 3 4 st1 st2 tod 1pps 50 75 50 75 clk out clk in clk ds1/e1 los optiswitch 9124-410G ps2 ps1 console eia-232 l a 10ge-xfp 25 l a 10ge-xfp 26 l a 10ge-xfp 27 l a 10ge-xfp 28 tmp fan mgt rst mgt eth ! 2 1 24 23 22 24 21 23 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 add drop exp com ms9-oadm8 in out em9005 ps/ac em9005 ps/dc caution this assembly contains electronically sensitive components 47 49 51 53 55 57 59 61 47 49 51 53 55 57 59 61 optiswitch 9124-410G ps2 ps1 console eia-232 l a 10ge-xfp 25 l a 10ge-xfp 26 l a 10ge-xfp 27 l a 10ge-xfp 28 tmp fan mgt rst mgt eth ! 2 1 24 23 22 24 21 23 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 add drop exp com ms9-oadm8 in out em9005 ps/ac em9005 ps/dc caution this assembly contains electronically sensitive components 47 49 51 53 55 57 59 61 47 49 51 53 55 57 59 61 3g node b not sure which solution best fts your needs? visit www.mrv.com or e-mail us at sales@mrv.com os9124 - 410g optical packet switched network
port numbering service interface options ports 1-16 10/100/1000baset - rj45 sfps (sfp-ga-r or sfp-gc-r) 100basefx - sgmii 100fx sfps 1000basefx - standard gige sfps 2.5gbps - 2000basefx - standard multi-rate sfps ports 17-18 10/100/1000baset - rj45 sfps (sfp-ga-r or sfp-gc-r) 100basefx - sgmii 100fx sfps 1000basefx - standard gige sfps port 19-20 100basefx - standard 100fx sfps 1000basefx - standard gige sfps port 21-24 tri-mode built-in options built-in 10/100/1000baset 100basefx - standard 100fx sfps 1000basefx - standard gige sfps port 25-28 10ge lan/wan(stm-64/oc192) phy - standard xfps multi-service slot wdm & ces services itu-t g.694.1 standard (dwdm) itu-t g.694.2 standard (cwdm) oadms, mux/demux e1/t1 ces stm-1/oc3 ces features and solution benefts os9124-410G platform is a high-performance system with non-blocking hardware and software architecture engineered for deployment in new and demanding packet-optical network environments to support the providers value-added services offering. by integrating packet switching and aggregation with wdm transport, the os9124-410G enables increased effciencies in bandwidth utilization, optimizing interface and simplifying the network by eliminating the need for dedicated hardware. for service providers who build next-generation optical networks, the consolidation of wdm services with intelligent traffc forwarding on the same platform offers signifcant costs savings in capital expenditure. multipurpose service interfaces the platform offers a unique combination of features and optical interfaces that enable easy and fexible feld confgurations while making it ideal for maintenance and inventory. the integration of cwdm / dwdm sfp / xfp eliminates the need for a transponder in the network, and offers better fber optimization along physical services separation with dedicated gigabit or 10g rates for premium optical services with the same concept of legacy leased-line services. ? all interfaces can be confgured as uni / nni to enable access to edge and intra-network services ? 100fx and 1000fx interfaces can be muxponded over 10ge interface at dedicated wavelength ? hot swappable xfp and sfp pluggable optics to insure diverse distance, cost and performance ? xfp slots support distances from short to long haul and dwdm pluggable optics ? sfp slots support distances from short to long haul, single strand and cwdm and dwdm optics ? 10ge interfaces software confgurable for 10ge lan or wan oc192/stm-64 ? all sfp and xfp interfaces enabled for remote optical level monitoring and alarm thresholds ? built-in rj45 electrical interfaces enabled for remote copper-tdr cable diagnostics end-to-end service provisioning and operation, administration & maintenance * mrvs pro-vision ? software enables complete easy-to-use gui tool to provision and activation management for packet-optical services. network monitoring supported by real-time sampling, or historical performance reporting for customer sla. the system is carrier-grade unix-based software that supports full fcaps industry standards to insure simplifed interoperability with existing operation support systems (oss) and 3rd party network management systems (nms) through northbound protocols, such as corba, snmp, tl1,http and xml. end-to-end service provisioning and activation across network infrastructure * * denotes future software release packet wdm
mef services ? uni type 1 and type 2 (mef21) ? external-nni & internal-nni ? epl, e-line, e-tree & e-lan C mef9 ? epl, e-line, e-tree & e-lan traffc mgm. C mef14 ? oam implementation agreement (ia) C mef17 ? all interfaces can be confgured as uni / enni packet switching services ? 200g (full-duplex) non-blocking wire-speed architecture ? confgurable jumbo frames per port / evc ? packet buffer management ? ieee802.1q and ieee802.1ad provider bridges - 4k active vlans / evcs - selective q-in-q stacking per acl criteria - confgurable ethertype values - private vlan ? transparent cross-connect mode - per system, per port or per evc non-learning mode ? learning table limit per vlan/port ? layer 2 control protocols tunneling ? uni protected ports / layer 1 fltering packet ring and link protection services ? sub 50 ms ring and dualChomed topologies ? elps g.8031 and erps g.8032 ? mstp ieee802.1s ? link aggregation (lag n+1) C static and lacp - load balancing based on l2-3-4 headers ? link level 1:1 loss of signal (los) protection ? cfm (oam) messages for fault detection and link fallback ? bi-directional link fault refection ? link fap protection and damping ? unidirectional link detection multicast and ip services* ? wire speed multicast replication ? igmp v1,v2 snooping , proxy and fast leave ? multicast vlan registration (mvr) protocol* ? multicast routing pim-sm* ? wire-speed ipv4 / ipv6* packet routing - rip, ospf, is-is, bgp-4, vrrp - secondary interfaces - dhcp server/client/relay layer 2.5 services* ? ethernet over mpls pseudowire with traffc engineering* ? h-vpls dual-homed spoke mtu-s (ler)* - ldp, rsvp-te, ospf-te, isis-te, cspf* ? mpls-transport profle C mpls-tp* availability ? 1:1 hot-swappable dual redundant power C ac/dc mix ? hot-swappable fans and flter ? temperature sensor for environmental alerts ? dual image & rollback processes ? modular control plane - master-os ? traffc management ? inbound & outbound traffc management per fow/evc ? in-service circuit parameters changes (hitless acl) ? dual-rate 3 color rate limit per fow or aggregate - granular cir/eir rates up to 10ge ? classifcation by any l2-3-4 criteria and mix - physical port, mac, ethertype, vlan, ip/tcp/udp ? ieee 802.1p (vpt), diffserv (ipv4 & ipv6 tc) ? marking/remarking profles between layers - 802.1p, dscp & mpls exp ? 8 hardware queues per port & confgurable sl ? per fow sla metrics - per uni, cos, evc, control protocols - 16,000 counters security ? wire-speed acls on l2-3-4 headers - up to 8k rules - ingress and egress acls - multiple actions in single acl ? cpu denial-of-service protection ? mac flters and mac limit per port/per vlan ? uni broadcast/multicast/unicast rate control ? flood limit of oam frames ? arp rate control ? dhcp option 82 & option 60 ? acl for management sessions from noc ? vacm C view-based access control model management & diagnostics tools ? industry standard cli ? out-of-band management - eia-232 console ? out-of-band ethernet management - dedicated eth port ? telnet, ssh v2, snmpv3, rmon (4 groups) ? port mirroring - ingress & egress traffc to analyzer port / vlan ? remote service/fow mirroring per acl ? ping, trace route, dns lookup, tcp dump (built-in sniffer) ? management acl for trusted connections (telnet/ssh/snmp) ? hierarchical administration policy ? radius / tacacs+ aaa for management sessions ? confguration load/save via ftp, secure copy (scp) ? ntp - network time protocol ? internal / remote syslog ? scripting tool for macro confgurations & maintenance ? action scheduler for automated rules (time/day/cycle) ? remote auto-confguration - dhcp server/client/relay ? ipv6 management* standard operation, administration & maintenance ? end-to-end service oam ieee802.1ag - connectivity fault management per service mep/mip - in-service evc loopbacks, linktrace & continuity check ? end-to-end performance measurement itu-t y.1731 & ip sla - per service jitter, latency & loss - nano sec precision - rfc2544 troughput measurements for service baseline - scalable up to 64 measurements fows ? efm link oam - ieee802.3ah - discovery, port-loopback, remote failure indication ? optical signal level monitoring (sfp sff-8472) ? copper cable diagnostics on rj45 ports ? remote failure notifcation / refection *future master-os? software release
mrv-os-9124 rev.3 10 -13 copyright ?2009 mrv communications, inc. all rights reserved. p/n description os9124-410G optiswitch? 9000 series multi-layer platform with 16 sfp (100fx/1000fx/2000fx) + 4 sfp (1000fx) + 4 x tri-mode rj45 10/100/1000baset or sfp (100fx/1000fx) + 4 x 10ge (lan/wan) + optional multi-service slot (ac/dc power supplies should be ordered separately) hot-swappable power supplies for os9000 series em9005-ps/ac ac power supply for the optiswitch? 9000 series (90-240v ac) em9005-ps/dc dc power supply for the optiswitch? 9000 series (-48v dc) accessories ms9000-blank blank panel for multi-service slot em9005-blank blank panel for power supply. em9005-br-2-c 23 mounting bracket ms9000-fg-a fiber guard tray for os9124-410G model em9005-fan-t spare part- fan tray for os9124-410G model master-os? - mpls ler software upgrade package for os9124-410G sw-upg-91mpls* enhanced software upgrade package for optiswitch? 9124-410G (master-os: label edge router mpls spoke vc - ldp, rsvp-te, cr-ldp, ospf-te, cspf) * for ordering codes of sfp/xfp and sgmii pluggable optics, please refer to mrvs web site os9000 - cwdm fber optimization modules o9adcxx 1 cwdm wavelengths df oadm module for os9000 o9adcxxyy 2 cwdm wavelengths df oadm module for os9000 o9adcxxyyzz 3 cwdm wavelengths df oadm module for os9000 o9adcxxyyzzww 4 cwdm wavelengths df oadm module for os9000 o9adcdxx 1 cwdm wavelengths df dual sided oadm module for os9000 o9adcdxxyy 2 cwdm wavelengths df dual sided oadm module for os9000 o9adcdxxyyzz 3 cwdm wavelengths df dual sided oadm module for os9000 o9adcdxxyyzzww 4 cwdm wavelengths df dual sided oadm module for os9000 o9adcdsxx 1 cwdm wavelengths sf dual sided oadm module for os9000 o9adcdsxxyy 2 cwdm wavelengths sf dual sided oadm module for os9000 o9adcdsxxyyzz 3 cwdm wavelengths sf dual sided oadm module for os9000 o9adcdsxxyyzzww 4 cwdm wavelengths sf dual sided oadm module for os9000 o9-mux/demux8 8 wavelengths cwdm multiplexer/demultiplexer module for os9000 os9000 - dwdm fber optimization modules o9addxx 1 dwdm wavelengths df dual sided oadm module for os9000 o9addxxyy 2 dwdm wavelengths df oadm module for os9000 o9addxxyyzz 3 dwdm wavelengths df oadm module for os9000 o9addxxyyzzww 4 dwdm wavelengths df oadm module for os9000 o9adddxx 1 dwdm wavelengths df dual sided oadm module for os9000 o9adddxxyy 2 dwdm wavelengths df dual sided oadm module for os9000 o9adddxxyyzz 3 dwdm wavelengths df dual sided oadm module for os9000 o9adddxxyyzzww 3 dwdm wavelengths df dual sided oadm module for os9000 o9adddsxx 1 dwdm wavelengths sf dual sided oadm module for os9000 o9adddsxxyy 2 dwdm wavelengths sf dual sided oadm module for os9000 o9adddsxxyyzz 3 dwdm wavelengths sf dual sided oadm module for os9000 o9adddsxxyyzzww 4 dwdm wavelengths sf dual sided oadm module for os9000 o9-mux/demux8db 8 wavelengths dwdm multiplexer/demultiplexer (ch#43 to ch#57) module for os9000 o9-mux/demux8dr 8 wavelengths dwdm multiplexer/demultiplexer (ch#21 to ch#35) module for os9000 technical specifcations regulatory compliance fcc part 15 (class a); emc directive: emission (class a) and immunity; lvd directive: electrical safety; ce marking; tuv-r mark (canada, usa); gost; rohs directive, reach svhc, weee directive; etsi, nebs level 3 certifed , c-tick. operating temperature 0 to 50 o c (32 to 122 o f) - short term operation 0 to 65 o c (32 to 149 o f) storage temperature -40 to +70 o c (-40 to 158 o f) humidity 10% to 85% non-condensing diagnostic leds power, system rst, temperature, fan, management , ps online/active /alarm , ports: link, activity, mgt rack mounting 19 or 23 racks , compact 2 ru height maintainability front facing system confguration: eliminates the need to dismount the system for maintenance or installation of new hardware following initial installation back-to-back installation in telco racks: doubling the port-per-rack density. performance non-blocking 200g (full-duplex) architecture full-wire packet forwarding on all ports 95m pps physical dimensions wxdxh (mm/inch) 447.6x300x88.1 mm 17.62x11.81x3.46 inch weight (kg. /lbs.) 5 kg/11 lbs (fully loaded with 2 ps 7kg /15.43lbs) mtbf hrs @25c /77f 245,104 power specifcations (ac/dc)hot swappable dual redundant power supplies ac input voltage line frequencies 50-60hz dc input voltage options power consumption(w) min. max. 90-240 vac -48vdc (-36vdc to -72vdc) 100w min 135w max hot swappable fans single tray C feld replaceable side-to-side airfow btu per hour (min/max) 341 / 460 ordering information


▲Up To Search▲   

 
Price & Availability of 9124-410G

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X